The determination of acetonitrile and acrylonitrile in fixed pollution source exhaust gas has been released as a national ecological environment standard, using activated carbon adsorption/solvent desorption gas chromatography method. This method is the current effective standard, which will be implemented from August 1, 2026 and replace the original HJ/T 37-1999.
Standard name: "Determination of Acetonitrile and Acrylonitrile in Waste Gas from Fixed Pollution Sources - Activated Carbon Adsorption/Solvent Desorption Gas Chromatography Method"
Standard number: HJ 37-2026
Implementation date: August 1, 2026
Published by: Ministry of Ecology and Environment of the People's Republic of China
Scope of application:
Organized emission of waste gas from fixed pollution sources
Determination of Acetonitrile and Acrylonitrile in the Air of Unorganized Emission Monitoring Points
Key technical points
Sampling method: Use activated carbon adsorption tubes (filled with coconut shell activated carbon, 800 mg for section A and 200 mg for section B) to enrich the target substance.
Sampling conditions:
Organized exhaust gas: Sampling volume of 10 L, heated to ≥ 120 ℃, flow rate of 0.1-1.0 L/min
Unorganized monitoring point air: sampling volume of 30 L, flow rate of 0.1-1.5 L/min
Desorption method: Use a mixture of carbon disulfide and acetone (1:1) for desorption, and quantify using external standard method.
Detection instrument: Gas chromatograph (FID detector), recommended chromatographic column size is 30 m × 0.53 mm × 1.00 μ m, 100% polyethylene glycol stationary phase.
Method performance (organized exhaust gas, sampling 10 L):
Acetonitrile detection limit: 0.3 mg/m ³, Acrylonitrile detection limit: 0.2 mg/m ³
Spiked recovery rates: Acetonitrile 95.1% -102%, Acrylonitrile 92.4% -101%
Relative standard deviation:<13% (inter laboratory)
Precautions
Safety warning: Acetonitrile, acrylonitrile, and desorption solvents (such as carbon disulfide) are all toxic. Operations must be carried out in a fume hood and protective equipment must be worn
Sample preservation:
Acetonitrile: Store at room temperature in the dark for ≤ 3 days; Below 8 ℃, it can be extended to 7 days
Acrylonitrile: stored at room temperature in the dark for ≤ 7 days; More stable below 8 ℃
Quality control:
One laboratory blank and one full program blank need to be analyzed for every 20 samples or batch
The correlation coefficient of the standard curve is ≥ 0.995
本标准规定了测定固定污染源有组织排放废气和无组织排放监控点空气中乙腈和丙烯腈的活性炭吸附/溶剂解吸-气相色谱法。
本标准适用于固定污染源有组织排放废气和无组织排放监控点空气中乙腈和丙烯腈的测定。
固定污染源有组织排放废气采样体积为10 L,解吸液体积为8.00 mL时,乙腈和丙烯腈的方法检出限分别为0.3 mg/m3和0.2 mg/m3,测定下限分别为1.2 mg/m3和0.8 mg/m3;无组织排放监控点空气采样体积为30 L,解吸液体积为8.00 mL时,乙腈和丙烯腈的方法检出限分别为0.09 mg/m3和0.07 mg/m3,测定下限分别为0.36 mg/m3和0.28 mg/m3。
名称:毛细管柱
固定相:交联键合聚乙二醇
规格:30m*0.53mm*1.0um
型号:PEG-20M
应用:HJ 37—2026固定污染源废气 乙腈和丙烯腈的测定 活性炭吸附/溶剂解吸-气相色谱法
适用于:
安捷伦490在线/便携,4890,5890,6890,7820,7890,8860,8890
岛津GC-14C,GC-2010,GC-2014,GC-2030
赛默飞1310,1300,1610,1600
瓦里安3800系列
布鲁克PE580,590,680,690
磐诺A90,福立GC9790,华爱,天瑞,天美,GC7900,川仪,北分瑞利,东西电子,鲁南瑞虹,捷岛/科晓




滕州市浩瀚色谱仪器技术服务有限公司
电话:0632-5667636
传真:0632-5667636
手机:15562228838,13963221227
地址:山东滕州市平行路(商务部和技术部)
邮箱:wangxiaoying9@126.com
QQ:1404939462
联系人:王经理
网址:www.haohansepu.com