安捷伦:5%角鲨烷;2%氢氧化钾玻璃柱测定水中三乙胺浓度
  • 安捷伦:5%角鲨烷;2%氢氧化钾玻璃柱测定水中三乙胺浓度

  • 发布时间:2026-2-2 11:49:37
  • 产品简介:
    名称:硬质玻璃柱

    固定相::5%角鲨烷;2%氢氧化钾。/Chromosorb103(80目~100目);

    规格:2m*3mm(内径)

    型号:5%squalane+2%KOH

    应用:GB/T 5750.8-2023《生活饮用水标准检验方法 第8部分:有机物指标》三乙胺
咨询热线:0632-5667636


机翻 · 通用领域
Triethylamine is slightly soluble in water, alkaline, and has a strong irritant effect on the respiratory system, which can easily cause pulmonary edema. Long term consumption of water sources rich in triethylamine poses a potential threat to human health. The GB 5749-2022 Sanitary Standards for Drinking Water does not specify any requirements for the limit of triethylamine.
Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. uses 5% squalane; 2% potassium hydroxide/Chromosorb103 (80-100 mesh); A headspace gas chromatography method was established to determine the concentration of triethylamine in water using a glass column In a constant temperature sealed container, triethylamine in the water sample is distributed between the gas and liquid phases until equilibrium is reached when it is strongly alkaline. The gas phase sample above the water sample is taken and detected using gas chromatography hydrogen flame detector (FID). The concentration of the analyte in the sample is determined by external standard method Experiments have shown that under alkaline conditions, triethylamine has good response linearity when tested by headspace gas chromatography, with a correlation coefficient greater than 0.998. The addition of inorganic salt sodium chloride can significantly improve the detection sensitivity, and the lower limit of determination can reach 0.58mg/L
Name: Hard Glass Column
Fixed phase: 5% squalane; 2% potassium hydroxide. /Chromosorb103 (80 to 100 orders);
Specification: 2m * 3mm (inner diameter)
Model: 5% squalane+2% KOH
Application: GB/T 5750.8-2023 "Standard Test Methods for Drinking Water Part 8: Organic Matter Index" Triethylamine
Suitable for:
Agilent 490 online/portable, 48905890689088608890
Shimadzu GC-14C, GC-2010, GC-2014, GC-2030
Thermo Fisher Scientific 1310130016101600
Varian 3800 Series
Brooke PE580590680690
Panno A90, Fuli GC9790, Huaai, Tianrui, Tianmei, GC7900, Chuanyi, Beifen Ruili, Dongxi Electronics, Lunan Ruihong, Jiedao/Kexiao

 

5A分子筛填充柱5A分子筛填充柱5A分子筛填充柱

三乙胺微溶于水,呈碱性,对呼吸系统具有强烈的刺激性,容 易引起肺水肿,长期饮用富含三乙胺的水源,对人类健康构 成潜在威胁。《GB 5749-2022 生活饮用水卫生标准》中未对 三乙胺限量指明要求。

 

浩瀚色谱(山东)应用技术开发有限公司,采用5%角鲨烷;2%氢氧化钾/Chromosorb103(80目~100目);玻璃柱建立了测定水中三乙胺浓度的顶空-气相色谱法.在恒温的密闭容器中,强碱性时水样中的三乙胺在气、液两相间分配直至达到平衡,取水样上方气相样品,使用气相色谱-氢火焰检测器(FID)进行检测,通过外标法测定样品中待测物质浓度.实验表明,在碱性条件下,三乙胺采用顶空气相色谱法测试时具备良好的响应线性,相关系数>0.998.加入无机盐氯化钠后可以显著提高检测灵敏度,测定下限可以达到0.58mg/L.

 

名称:硬质玻璃柱

固定相::5%角鲨烷;2%氢氧化钾。/Chromosorb103(80目~100目);

规格:2m*3mm(内径)

型号:5%squalane+2%KOH

应用:GB/T 5750.8-2023《生活饮用水标准检验方法 第8部分:有机物指标》三乙胺

 

适用于:

安捷伦490在线/便携,4890,5890,6890,7820,7890,8860,8890

岛津GC-14C,GC-2010,GC-2014,GC-2030

赛默飞1310,1300,1610,1600

瓦里安3800系列

布鲁克PE580,590,680,690

磐诺A90,福立GC9790,华爱,天瑞,天美,GC7900,川仪,北分瑞利,东西电子,鲁南瑞虹,捷岛/科晓

联系人
手机号码
电子邮件
验证码
看不清楚?点击换张图片
我要评论:

(内容最多500个汉字,1000个字符)

验 证 码 :
提交信息

网站首页  |  产品展示  |  关于我们  |  新闻资讯  |  技术服务  |  营销招聘  |  公司资质  |  联系我们

网站ICP备案号:鲁ICP备18012860号

鲁公网安备: 37048102006522号

浩瀚色谱(山东)应用技术开发有限公司
地址:山东滕州市平行路(商务部和技术部)
电话:0632-5667636   传真:0632-5667636
手机:15562228838,13963221227  邮箱:wangxiaoying9@126.com

 

技术支持:牵牛建站 | 中科商务网  | 网站管理