联系我们

 

联系我们

浩瀚色谱(山东)应用技术开发有限公司
电话:0632-5667636
传真:0632-5667636
手机:15562228838,13963221227

地址:山东滕州市平行路(商务部和技术部)
邮箱:wangxiaoying9@126.com
QQ:1404939462
联系人:王经理
网址:www.haohansepu.com

3%OV-17填充柱测定固定污染源排气中氯乙烯
  • 3%OV-17填充柱测定固定污染源排气中氯乙烯

  • 发布时间:2025-12-24 21:10:54
  • 产品简介:
    名称:不锈钢柱

    规格:2m*3mm,80-100目

    型号:3%OV-17/硅烷化101白色担体

    应用:HJ/T 34-1999固定污染源排气中氯乙烯的测定 气相色谱法
咨询热线:0632-5667636

本标准适用于固定污染源有组织排放和无组织排放的氯乙烯测定。当色谱进样量为3ml时,方法的检出限为0.08mg/m3,定量测定的浓度下限为0.26mg/m3,上限可达1×104mg/m3浓度范围。

 

浩瀚色谱(山东)应用技术开发有限公司,建立工作场所、环境空气、废气中的氯乙烯热解吸-气相色谱测定方法.方法:Carboxen1000吸附管吸附工作场所、环境空气中氯乙烯、二氯乙烷经热解吸-气相色谱进行定性及定量分析.结果:标准曲线相关系数达到0.9998,检出限30 ng/样品,最低检出浓度0.025 mg/m3(以采集1.5L空气计),解吸效率91.8%~94.9%,精密度0.65%~4.7%,吸附管净化好后和样品采集后用黄铜螺帽密封放入密封的塑料袋中常温可保存一周.结论:该方法可用于工作场所、环境空气、废气、室内空气中氯乙烯浓度的检测.

 

名称:不锈钢

规格:2m*3mm,80-100目

型号:3%OV-17/硅烷化101白色担体

应用:HJ/T 34-1999固定污染源排气中氯乙烯的测定 气相色谱法

 

 

应用:

安捷伦490在线/便携,4890,5890,6890,7820,7890,8860,8890

岛津GC-14C,GC-2010,GC-2014,GC-2030

赛默飞1310,1300,1610,1600

瓦里安3800系列

布鲁克PE580,590,680,690

磐诺A90,福立GC9790,华爱,天瑞,天美,GC7900,川仪,北分瑞利,东西电子,鲁南瑞虹,捷岛/科晓

 

5A分子筛填充柱5A分子筛填充柱5A分子筛填充柱5A分子筛填充柱

 

This standard is applicable to the determination of vinyl chloride emissions from organized and unorganized sources of fixed pollution. When the chromatographic injection volume is 3ml, the detection limit of the method is 0.08mg/m3, the lower limit of quantitative determination concentration is 0.26mg/m3, and the upper limit can reach a concentration range of 1 × 104mg/m3.
Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. establishes a thermal desorption gas chromatography method for the determination of vinyl chloride in workplaces, ambient air, and exhaust gases Method: Carboxen1000 adsorption tube was used to adsorb vinyl chloride and dichloroethane in the workplace and ambient air for qualitative and quantitative analysis by thermal desorption gas chromatography Result: The correlation coefficient of the standard curve reached 0.9998, the detection limit was 30 ng/sample, the lowest detection concentration was 0.025 mg/m3 (based on collecting 1.5L of air), the desorption efficiency was 91.8% to 94.9%, and the precision was 0.65% to 4.7%. After purification of the adsorption tube and sample collection, it was sealed with brass nuts and stored in a sealed plastic bag at room temperature for one week Conclusion: This method can be used for detecting the concentration of vinyl chloride in workplaces, ambient air, exhaust gases, and indoor air
Name: Stainless Steel Column
Specification: 2m * 3mm, 80-100 mesh
Model: 3% OV-17/Silanized 101 White Carrier
Application: HJ/T 34-1999 Determination of vinyl chloride in exhaust gas from stationary sources Gas chromatography method
Application:
Agilent 490 online/portable, 48905890689088608890
Shimadzu GC-14C, GC-2010, GC-2014, GC-2030
Thermo Fisher Scientific 1310130016101600
Varian 3800 Series
Brooke PE580590680690
Panno A90, Fuli GC9790, Huaai, Tianrui, Tianmei, GC7900, Chuanyi, Beifen Ruili, Dongxi Electronics, Lunan Ruihong, Jiedao/Kexiao

 

 

联系人
手机号码
电子邮件
验证码
看不清楚?点击换张图片
我要评论:

(内容最多500个汉字,1000个字符)

验 证 码 :
提交信息

网站首页  |  产品展示  |  关于我们  |  新闻资讯  |  技术服务  |  营销招聘  |  公司资质  |  联系我们

网站ICP备案号:鲁ICP备18012860号

鲁公网安备: 37048102006522号

浩瀚色谱(山东)应用技术开发有限公司
地址:山东滕州市平行路(商务部和技术部)
电话:0632-5667636   传真:0632-5667636
手机:15562228838,13963221227  邮箱:wangxiaoying9@126.com

 

技术支持:牵牛建站 | 中科商务网  | 网站管理