2 0世纪 80年代 ,一些美国商人将受二溴乙烷污染的粮食出口中国.为解决这一问题 ,卫生部责令卫生部食品卫生监督检验所牵头解决检测方法问题.检测方法解决后 ,1984年 6月部分口岸对 17条美国船的 81个样品进行了检测 ,其中 17个样品检出二溴乙烷 ,并且一些样品污染严重. 1984年 10月大连等 5口岸对 2 2条美国船的 185个样品进行检验 ,其中 4 9个样品中含二溴乙烷.同期未在其他国家的粮食中检出二溴乙烷.根据二溴乙烷的毒性和参考部分国家及国际组织对二溴乙烷的管理原则 ,确定了我国的二溴乙烷国家标准检测方法及残留标准 (原粮≤ 10ppb).
浩瀚色谱(山东)应用技术开发有限公司,研制《Ucone oil LB-550X 色谱柱应用岛津》,在岛津,安捷伦,赛默飞,瓦里安,PE,布鲁克上,测定粮食中二xiu乙烷残留量结果准确,满意。
名称:不锈钢填充柱
规格:1/8" *2M,(60/80)
型号:15% Ucone oil LB-550X on Chromosorb WAW
zui高使用温度:160°C
编号:20251211001
应用:GB 4790-1984粮食中二xiu乙烷残留量卫生标准及检验方法
GB/T 5009.73-2003粮食中二xiu乙烷残留量的测定
本标准适用于用二xiu乙烷熏蒸的粮食。
适用于:
安捷伦490在线/便携,4890,5890,6890,7820,7890,8860,8890
岛津GC-14C,GC-2010,GC-2014,GC-2030
赛默飞1310,1300,1610,1600
瓦里安3800系列
布鲁克PE580,590,680,690
磐诺A90,福立GC9790,华爱,天瑞,天美,GC7900,川仪,北分瑞利,东西电子,鲁南瑞虹,捷岛/科晓




In the 1980s, some American businessmen exported food contaminated with dibromoethane to China To address this issue, the Ministry of Health has ordered the Food Safety Supervision and Inspection Institute of the Ministry of Health to take the lead in solving the testing method problem After the detection method was resolved, 81 samples from 17 American ships were tested at some ports in June 1984. Among them, 17 samples were found to contain dibromoethane, and some samples were severely contaminated In October 1984, 185 samples from 22 American ships were inspected at 5 ports including Dalian, among which 49 samples contained dibromoethane Dibromoethane was not detected in grains from other countries during the same period Based on the toxicity of dibromoethane and reference to the management principles of some countries and international organizations for dibromoethane, the national standard detection method and residue standard for dibromoethane in China have been determined (raw grain ≤ 10pppb)
Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. has developed the "Ucone oil LB-550X chromatographic column application Shimadzu" in Shimadzu, Agilent, Thermo Fisher, and Varian, PE, On Brooke, the determination of residual ethylene oxide in grains was accurate and satisfactory.
Name: Stainless Steel Filled Column
Specification: 1/8 "* 2M, (60/80)
Model: 15% Ucone oil LB-550X on Chromosorb WAW
Maximum operating temperature: 160 ° C
Number: 20251211001
Application: GB 4790-1984 Hygienic Standards and Testing Methods for Residual Ethane in Grain
GB/T 5009.73-2003 Determination of Residual Ethane in Grains
This standard is applicable to grains fumigated with ethylene glycol.
Suitable for:
Agilent 490 online/portable, 48905890689088608890
Shimadzu GC-14C, GC-2010, GC-2014, GC-2030
Thermo Fisher Scientific 1310130016101600
Varian 3800 Series
Brooke PE580590680690
Panno A90, Fuli GC9790, Huaai, Tianrui, Tianmei, GC7900, Chuanyi, Beifen Ruili, Dongxi Electronics, Lunan Ruihong, Jiedao/Kexiao