HJ/T 33-1999 固定污染源排气中甲醇的测定 方法中所使用的 石墨化碳黑填充柱
该方法原理是利用载气(高纯氮气)将样品通过填充柱,甲醇等组分在柱中分离后,进入氢火焰离子化检测器(FID) 进行检测,通过保留时间定性,峰高或峰面积定量。
适用范围:适用于固定污染源有组织排放(如烟囱、管道)和无组织排放(如车间边界)中甲醇的测定。
方法性能:标准中提到,当进样量为1.0 ml时,方法的检出限为2 mg/m³,定量测定范围一般为5.0 - 104 mg/m³。另有应用表明其最低检出浓度可达0.2 mg/m³6,或0.07 mg/m³(通过富集采样后)。
样品处理:通常采用硅胶管吸附或蒸馏水/去离子水吸收的方式采集废气中的甲醇,再经热解吸或直接进样分析。
名称:甲醇专用填充柱
型号:5%Carbowax20M Carbopack B
规格:2m*3mm,80-120目
浩瀚色谱(山东)应用技术开发有限公司,研制生产的《固定污染源排气中甲醇的测定岛津色谱柱》柱效高,分离好,峰型对称,用标准加入法测得回收率在101%~103%之间,测定值的相对标准偏差(n=5)均小于2%,结果满意。
适用于:
安捷伦490在线/便携,4890,5890,6890,7820,7890,8860,8890
岛津GC-14C,GC-2010,GC-2014,GC-2030
赛默飞1310,1300,1610,1600
瓦里安3800系列
布鲁克PE580,590,680,690
磐诺A90,福立GC9790,华爱,天瑞,天美,GC7900,川仪,北分瑞利,东西电子,鲁南瑞虹,捷岛/科晓







The graphitized carbon black packed column used in the determination method of methanol in fixed pollution source exhaust gas HJ/T 33-1999
The principle of this method is to use a carrier gas (high-purity nitrogen) to pass the sample through a packed column. After separating components such as methanol in the column, it enters a hydrogen flame ionization detector (FID) for detection. Qualitative analysis is performed by retention time, and quantitative analysis is performed by peak height or peak area.
Scope of application: Suitable for the determination of methanol in organized emissions (such as chimneys and pipelines) and unorganized emissions (such as workshop boundaries) from fixed pollution sources.
Method performance: As mentioned in the standard, when the injection volume is 1.0 ml, the detection limit of the method is 2 mg/m ³, and the quantitative determination range is generally 5.0-104 mg/m ³. Another application shows that its minimum detectable concentration can reach 0.2 mg/m ³ 6, or 0.07 mg/m ³ (after enrichment sampling).
Sample processing: Methanol in exhaust gas is usually collected by adsorption with silicone tubing or absorption with distilled/deionized water, and then analyzed by thermal desorption or direct injection.
Name: Methanol specific packed column
Model: 5% Carbowax20M Carbopack B
Specification: 2m * 3mm, 80-120 mesh
Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. has developed and produced the Shimadzu chromatography column for the determination of methanol in exhaust gas from fixed pollution sources. The column has high efficiency, good separation, and symmetrical peak shapes. The recovery rate measured by standard addition method is between 101% and 103%, and the relative standard deviation (n=5) of the measured values is less than 2%. The results are satisfactory.
Suitable for:
Agilent 490 online/portable, 48905890689088608890
Shimadzu GC-14C, GC-2010, GC-2014, GC-2030
Thermo Fisher Scientific 1310130016101600
Varian 3800 Series
Brooke PE580590680690
Panno A90, Fuli GC9790, Huaai, Tianrui, Tianmei, GC7900, Chuanyi, Beifen Ruili, Dongxi Electronics, Lunan Ruihong, Jiedao/Kexiao
滕州市浩瀚色谱仪器技术服务有限公司
电话:0632-5667636
传真:0632-5667636
手机:15562228838,13963221227
地址:山东滕州市平行路(商务部和技术部)
邮箱:wangxiaoying9@126.com
QQ:1404939462
联系人:王经理
网址:www.haohansepu.com