gdx102填充柱气相色谱测定化妆品中甲醇
  • gdx102填充柱气相色谱测定化妆品中甲醇

  • 发布时间:2025-6-30 10:33:55
  • 产品简介:
    名称:不锈钢填充柱
    规格:2m*4mm
    型号:GDX-102,60-80目
    zui-gao使用温度:270°C

    应用:GB/T 7917.4-1987 化妆品卫生化学标准检验方法 甲醇
咨询热线:0632-5667636

甲醇在人体有蓄积作用,主要经呼吸道、胃肠道和皮肤吸收,其最终代谢产物为甲醛和甲酸.近年研究表明,甲醛很快代谢成甲酸,急性中毒引起的代谢性酸中毒和眼部损害,主要与甲酸含量相关.因甲醇的毒性较强,故我国化妆品卫生标准规定甲醇为限用物质.在保健用品中的允许浓度为2 000 mg/kg

 

浩瀚色谱(山东)应用技术开发有限公司:建立快速、灵敏的甲醇测定方法。方法 :采用程度升温气相色谱法测定化妆品中甲醇。结果 :甲醇的分离大为改善 ,具有比现行国标更好的精密度。结论 :本法具有重现性好 ,准确度高 ,稳定、快速的特点 。

 

名称:不锈钢填充柱

规格:2m*4mm

型号:GDX-102,60-80目

zui-gao使用温度:270°C

应用:GB/T 7917.4-1987 化妆品卫生化学标准检验方法 甲醇

 

本标准适用于含乙醇的化妆品中甲醇含量的测定。

注:依据国家标准全文公开系统该标准编号已调整为GB/T,已作为推荐性国家标准。

 

适用于:

安捷伦490在线/便携,4890,5890,6890,7820,7890,8860,8890

岛津GC-14C,GC-2010,GC-2014,GC-2030

赛默飞1310,1300,1610,1600

瓦里安3800系列

布鲁克PE580,590,680,690

磐诺A90,福立GC9790,华爱,天瑞,天美,GC7900,川仪,北分瑞利,东西电子,鲁南瑞虹,捷岛/科晓

 

5A分子筛填充柱5A分子筛填充柱5A分子筛填充柱5A分子筛填充柱5A分子筛填充柱5A分子筛填充柱

Methanol accumulates in the human body and is mainly absorbed through the respiratory tract, gastrointestinal tract, and skin. Its final metabolites are formaldehyde and formic acid Recent studies have shown that formaldehyde is rapidly metabolized into formic acid. Metabolic acidosis and eye damage caused by acute poisoning are mainly related to formic acid content Due to the strong toxicity of methanol, the hygiene standards for cosmetics in China stipulate that methanol is a restricted substance The allowable concentration in healthcare products is 2000 mg/kg

Haohan Chromatography (Shandong) Application Technology Development Co., Ltd.: Establish a rapid and sensitive methanol determination method. Method: The degree of temperature rise gas chromatography was used to determine methanol in cosmetics. Result: The separation of methanol has been greatly improved, with better precision than the current national standard. Conclusion: This method has the characteristics of good reproducibility, high accuracy, stability, and speed.

Name: Stainless Steel Filled Column

Specification: 2m * 4mm

Model: GDX-102, 60-80 mesh

Zui gao operating temperature: 270 ° C

Application: GB/T 7917.4-1987 Standard Test Method for Hygienic Chemistry of Cosmetics - Methanol

This standard is applicable to the determination of methanol content in cosmetics containing ethanol.

Note: According to the national standard full-text disclosure system, the standard number has been adjusted to GB/T and has been adopted as a recommended national standard.

Applicable to:

Agilent 490 online/portable, 48905890689088608890

Shimadzu GC-14C, GC-2010, GC-2014, GC-2030

Thermo Fisher Scientific 1310130016101600

Varian 3800 Series

Brooke PE580590680690

Panno A90, Fuli GC9790, Huaai, Tianrui, Tianmei, GC7900, Chuanyi, Beifen Ruili, Dongxi Electronics, Lunan Ruihong, Jiedao/Kexiao

联系人
手机号码
电子邮件
验证码
看不清楚?点击换张图片
我要评论:

(内容最多500个汉字,1000个字符)

验 证 码 :
提交信息

网站首页  |  产品展示  |  关于我们  |  新闻资讯  |  技术服务  |  营销招聘  |  公司资质  |  联系我们

网站ICP备案号:鲁ICP备18012860号

鲁公网安备: 37048102006522号

浩瀚色谱(山东)应用技术开发有限公司
地址:山东滕州市平行路(商务部和技术部)
电话:0632-5667636   传真:0632-5667636
手机:15562228838,13963221227  邮箱:wangxiaoying9@126.com

 

技术支持:牵牛建站 | 中科商务网  | 网站管理